FlexLine steam humidifiers - flexibility that pays off.
The new generation of steam humidifiers from the medium-sized German company Hygromatik. As the successor to the Hygromatik CompactLine steam generators, the FlexLine offers a basic model with 10 performance classes to meet the different requirements for steam quantities. The FlexLine steam humidifier impresses with its high flexibility and availability, which is ensured by its modular Modular system modular system. Due to this design, the basic model serves as the basis for all further configuration options Configuration optionswhich allows the FlexLine to be individually adapted to the various requirements in the air-conditioning and room humidification sector. The exclusive and intelligent system was awarded in three categories and the FlexLine steam humidifiers were named "Best Product 2018" with the Plus x Award. Not only for the air conditioning for common rooms such as offices and the like, but also for the Humidity control of the bio sauna.
Steam generation with radiators
Humidification with HygroMatik steam humidifiers is basically suitable for
all water qualities suitable. Particularly low-maintenance is the operation with
softened or demineralized water.
Heating elements heat the water in a steam cylinder as in an immersion heater to produce
pressureless, hygienic steam.
HygroMatik uses resistance heating elements made of a highly corrosion-resistant alloy in all radiator steam humidifiers. They convince by an extremely
high control accuracy, long service life and an almost
uninterrupted and maintenance-free operation when using softened or fully demineralized water
Download Functional Diagram Radiator Steam Humidifier FlexLine Climate Unit
FlexLine connection options
The FlexLine offers a wide range of options with which the steam humidifier can be adapted to the individual spatial conditions. We will be happy to advise you on the available connection options
HyCool (integrated waste water cooling),
HyFlow (DvGW-certified system separator),
Cylinder Star (improved controllability at high supply voltage) and
SuperFlush (cylinder flushing device). We are always interested in the personally best steam solution for your project.
Operation of FlexLine steam humidifiers
All HygroMatik FlexLine steam generators are equipped with a capacitive
3,5" touch display equipped. Operation and programming is done via a flat and simple menu structure according to the logic of modern smartphones. Software updates can be carried out quickly and easily via USB stick.
- Operating status is visualized by clear pictograms
- Navigation is simple and fast
- System messages and information are displayed in plain text
- Service messages are output with date and time
- Real-time clock
Sustainability and quality promise
HygroMatik promises a particularly long service life due to the qualitative development of its products long service life. The FlexLine steam humidifiers in particular feature technologies that have perfected the effective use of energy and resources. This enables the FlexLine steam generators to have a particularly low wear and maintenance maintenance.
- Load shedding between 25% and 100%: programmable temporary or permanent adjustments of operation
- many years of continuous use thanks to improved base materials that give the reusable cylinders even greater temperature resistance and dimensional stability
- separable steam cylinder that can be easily opened and cleaned without chemicals
- Durability: corrosion-resistant stainless steel housing with additional powder coating
- robust blowdown pump to remove hardness components for long operating times and low maintenance requirements
- market-wide highest safety standard among radiator steam humidifiers due to integrated circuit breaker
Service functions
The HygroMatik FlexLine is equipped with smart service functions and innovative features for operational safety, achieving a new level of safety, control and overview.
- Diagnostic mode: start via touch display without commissioning the unit
- Service message: selectable service intervals are calculated and issued by the unit according to the amount of steam produced
- Status messages: Intelligent control avoids damage and expensive service calls
- detailed messages: Deviations can be identified and remedied more quickly
Areas of application FlexLine Climate
Office and conference rooms
The performance of employees essentially depends on motivation, concentration and health aspects. A healthy room climate with optimum air humidity provides the ideal basis for this and also saves energy costs.
Hotels and conference centers
One of the most important tasks in the field of activity of hotels and conference centers is to provide guests with a pleasant stay. A healthy and work-friendly indoor climate plays an essential role in this.
Universities and educational institutions
When people feel comfortable, they are more receptive and more focused on their work. In rooms with many people, however, individuals quickly feel tired. Optimizing the air humidity can help here.
Shopping centers and department stores
More and more customers want a shopping experience in a feel-good atmosphere. Optimum air humidity makes a decisive contribution to a pleasant room climate in which people enjoy spending more time.
Museums and galleries
Museums and galleries often house valuables of inestimable value which, due to their age or condition, require a controllable or constant room climate. Humidification is essential to counteract damage.
Hospitals and medical practices
In the rooms of hospitals and medical practices, the treatment and recovery of patients is the primary concern. A health-promoting room climate is therefore a very important component in the overall offer of a medical facility.
Libraries and antiquarian bookshops
Depending on the temperature, paper takes moisture from the ambient air or releases it into it. If the air is too dry, paper becomes brittle and cracked. Regulated humidification prevents aging and damage to books.
Cruise and offshore
Cruise ships require a tremendous amount of cooling power for air conditioning. Adiabatic cooling systems generate this efficiently and cost-effectively. Regulated humidity also creates a comfortable and healthy climate below deck
Technical data FlexLine air-conditioning radiators
Unit type |
FLH03 |
FLH06 |
FLH09 |
FLH15 |
FLH25 |
FLH30 |
FLH40 |
FLH50 |
FLH80 |
FL100 |
Steam capacity [kg/h] |
2,7-3,3 |
5,5-6,5 |
8,2-9,8 |
13,7-16,4 |
22,7-27,1 |
27,4-32,7 |
36,5-43,5 |
45,5-54,3 |
73,0-87,0 |
91,0-108,6 |
Steam cabin size [m³] |
3,37-4,12 |
6,87-8,12 |
10,25-12,25 |
17,12-20,5 |
28,37-33,87 |
34,25-40,87 |
45,62-54,37 |
56,87-67,87 |
91,25-108,75 |
113,75-135,62 |
Electrical connection (1)
|
220-240 v / 1 Ph / 50-60 Hz |
380-415 v / 3 Ph / 50-60 Hz |
Electrical power [kW] |
2,1-2,4 |
4,1-4,9 |
6,2-7,3 |
10,3-12,3 |
17,1-20,3 |
20,6-24,5 |
27,3-32,6 |
34,1-40,7 |
2 x 27,3-32,6 |
2 x 34,1-40,7 |
Current consumption [a] |
9,4-10,2 |
18,7-20,4 |
10,7-11,7 |
16,0-17,5 |
15,6-17,1 |
25,9-28,3 |
31,3-34,1 |
41,5-45,4 |
51,8-56,6 |
2 x 41,5-45,4 |
2 x 51,8-56,6 |
Fuse [a] (2)
|
1 x 16 |
1 x 25 |
3 x 16 |
3 x 20 |
3 x 32 |
3 x 35 |
3 x 50 |
3 x 63 |
2 x 3 x 50 |
2 x 3 x 63 |
Number of steam cylinders |
1 |
2 |
Control |
FlexLine mainboard with capacitive 3.5" touch color display |
Steam hose connection [mm] |
1 x 25 |
1 x 40 |
1 x 40 (3)
|
2 x 40 |
4 x 40 |
Empty weight [kg] |
18 |
19 |
25 |
36 |
37 |
75 |
80 |
Max. Filling volume [L] |
5 |
14 |
36 |
71 |
Operating weight [kg] |
23 |
24 |
40 |
72 |
74 |
147 |
152 |
Unit size WxHxD [mm] (4)
|
540 x 535 x 320 |
540 x 695 x 320 |
640 x 785 x 420 |
1170 x 785 x 420 |
Water connection |
demineralized water / purified condensate / partly softened water / tap water of different qualities, 1-10 bar, for 3/4" male thread |
Waste water connection |
Connection piece ø 1 1/4" |
2 x connecting piece ø 1 1/4" |
1) Other voltages on request
2) 1.1 times current consumption after full blowdown. Observe tripping characteristics of circuit breakers. If necessary, select next higher circuit breaker level
3) Including Y-piece DN40
4) External dimensions of width and depth. Height including drain socket